-40%

Soviet USSR military Dosimeter of DP-24 gamma radiation Vintage, New

$ 29.04

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • Modified Item: No
  • MPN: Does Not Apply
  • Refund will be given as: Money Back
  • Radiation Detector Type: Geiger Counter
  • All returns accepted: Returns Accepted
  • Condition: New
  • Brand: DP
  • Item must be returned within: 30 Days
  • Model: DP 24
  • Country/Region of Manufacture: Russian Federation

    Description

    Dosimeter DP-24 is designed to measure individual exposure doses of gamma radiation.
    Not used
    PRICE FOR ONE COMPLECT
    without battery
    Technical characteristics of dosimeters DP-24:
    Temperature - from -40 ° C to + 50 ° C;
    The measuring range is from 0Р to 50Р;
    The exposure dose rates range from 0.5R / h to 200R / h;
    The energy range is from 0.1 MeV to 2 MeV in the absence of beta-
    radiation with energy above 0.6 MeV;
    The dosage of DP-24 dosage doses measured by the device is made on a scale located inside the dosimeter and calibrated in X-rays;
    The basic measurement error when irradiated with a Co60 source under normal conditions does not exceed ± 10% of the final value of the scale.
    Note.
    Normal conditions are: temperature + 20 ° C ± 5 ° C, atmospheric pressure 105Pa ± 4Pa (750mmHg ± 30mmHg), relative humidity 65% ​​± 15%;
    The efficiency of radiation detection with a dosimeter DP-24 device over the energy range in the range from 0.1 MeV to 2 MeV during measurements does not exceed ± 40% of the readings obtained by irradiation with a Co60 source
    ;
    Self-discharge dosimeter does not exceed:
    a) under normal conditions for 24 hours - 2 divisions;
    b) in the conditions of temperature + 50 ° C ± 2 ° C for 24 hours - 3 divisions;
    c) in conditions of temperature -40 ° C ± 2 ° C for 4 hours - 2 divisions;
    d) in conditions of relative humidity 95% ± 3% and temperature + 30 ° C ± 2 ° C for 48 hours - 3 divisions;
    The instability of the readings in time with a triple irradiation of the device dosimeter DP-24 does not exceed ± 5% of the final value of the scale;
    The dosimeter is hermetically sealed;
    The diaphragm of the dosimeter can withstand at least 10,000 charge cycles;
    Charging the device dosimeter DP-24 is made from the charger ZD-
    5 or any other constant voltage source having a smooth voltage regulation in the range from 180V to 250V at a temperature from -40ºС to + 50 ° С;
    Note. Required characteristics of ZD-5 are provided after a self-heating time of one minute;
    The voltage at the output of the ZD-5 is infinitely adjustable within the limits of:
    -
    the lower limit is ≤180V;
    - the upper limit is ≥250V;
    The current consumption of the ZD-5 from the power source does not exceed 200mA, which ensures the continuous operation of the dosimeter DP-24 for 30 hours from one set of elements at the beginning of their discharge;
    The charger ZD-5 is splash-proof;
    The device dosimeter DP-
    24 keeps working after stay at:
    a) temperature + 65 ° C ± 2 ° C;
    b) temperature -50 ° C ± 2 ° C;
    c) a maximum relative humidity of 95% ± 3% and a temperature of + 30 ° C ± 2 ° C;